Siemens 6GK59911AD008AA0
Scalance X ACCESSORY, SFP991-1 1 X 100MBIT,S LC-PORT OPTICAL MULTIMODE GLASS UP TO MAX. 5 KM
This Siemens 6GK59911AD008AA0 is supplied brand new by PartLogic for machine networks, control system connectivity, data transfer, automation panels and maintenance applications. It forms part of our Industrial automation > Networking > Industrial ethernet range and is referenced internally as PartLogic SKU PL27103426175.
Before ordering, please confirm the manufacturer part number, product specifications and compatibility with your existing equipment. If you are replacing a failed, obsolete or hard-to-find part, contact PartLogic and we can help check suitability or source related components.
| Technical Product Detail Page | https://i.siemens.com/1P6GK5991-1AD00-8AA0 |
| number of electrical/optical connections / for network components or terminal equipment / maximum | 1 |
| number of optical interfaces / for network components or terminal equipment / maximum | 1 |
| number of 100 Mbit/s LC ports | 1 |
| design of the optical interface / for network components or terminal equipment | LC |
| wavelength / of the optical interface | 1300 nm; Multi-mode |
| of the transmitter output / minimum | -24 dB |
| of the transmitter output / maximum | -14 dB |
| of the receiver input / maximum | -12 dB |
| optical sensitivity relating to 1 mW / of the receiver input / minimum | -31 dB |
| attenuation factor / of the FOC transmission link / minimum necessary | 0 dB |
| range / at the optical interface / depending on the optical fiber used | 0 ... 5 km |
| transmission method / for connection type 1 | 100BASE-FX |
| during operation | -40 ... +85 °C9.85 kg |
| during storage | -40 ... +85 °C |
| during transport | -40 ... +85 °C |
| note | A maximum operating temperature of +85 °C is permissible for a duration of 16 hours |
| relative humidity / at 25 °C / without condensation / during operation / maximum | 95 % |
| protection class IP | IP20 |
| design | SFP Module |
| width | 14 mm |
| height | 9 mm |
| depth | 57 mm |
| net weight | 0.01 kg |
| fastening method | latched |
| for FM | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 |
| for hazardous zone | EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X |
| for safety / from CSA and UL | UL 62368-1 and CAN/CSA C22.2 No. 62368-1:19 |
| for emitted interference | EN 61000-6-4:2007 (Class A) |
| for interference immunity | EN 61000-6-2:2005 |
| certificate of suitability | EN 61000-6-2:2005, EN 61000-6-4:2007 |
| CE marking | Yes |
| C-Tick | Yes |
| KC approval | No |
| CCC / for hazardous zone according to GB standard | Yes; GB3836.1, GB3836.8 |
| CCC / for hazardous zone according to GB standard / as marking | Ex nA IIC T4 Gc |
| French marine classification society (BV) | Yes |
| MTBF | 490 a |
| product function / is supported / identification link | Yes; acc. to IEC 61406-1:2022 |
| Environmental Product Declaration | Yes |
| total | 11.56 kg |
| during manufacturing | 1.7 kg |
| after end of life | 0.01 kg |
| to website: Selection guide for cables and connectors | https://support.industry.siemens.com/cs/ww/en/view/109766358 |
| to web page: selection aid TIA Selection Tool | https://www.siemens.com/tstcloud |
| to website: Industrial communication | https://www.siemens.com/simatic-net |
| to web page: SiePortal | https://sieportal.siemens.com/ |
| to website: Image database | https://www.automation.siemens.com/bilddb |
| to website: CAx-Download-Manager | https://www.siemens.com/cax |
| to website: Industry Online Support | https://support.industry.siemens.com |
| security information | Siemens provides products and solutions with industrial cybersecurity functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial cybersecurity concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. For additional information on industrial cybersecurity measures that may be implemented, please visit www.siemens.com/cybersecurity-industry. Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Cybersecurity RSS Feed under https://www.siemens.com/cert. (V4.7) |
Struggling to find what you're looking for?
Can’t find what you’re looking for? Get in touch — we can source it for you.